# Tissue preparation changes protein maps, a benchmark shows

Protocol choices change the signals and cells that software can identify. The study concerns laboratory measurements without establishing clinical benefit.

https://news.lyntev.com/news/ffpe-tissue-preparation-protein-imaging-benchmark

By Wellinton Oliveira, CEO of Lyntev. Published: 27 November 2026, 10:30

![Eight tissue micrographs with differently coloured protein stains, marker labels and 500-micrometre scale bars.](https://news.lyntev.com/media/historias/preparacao-tecidos-ffpe-imagem-proteinas-fa932f94-685.webp)

PhenoCycler-Fusion micrographs of tissue containing osteosarcoma lung metastases, published by Ryan A. Lacinski and colleagues in 2024. Different markers illustrate multiplexed imaging of FFPE tissue; these are not samples or results of the 2026 benchmark. Full panel d of figure 1 retained, with original labels and 500 µm scale bars, without enlargement. Ryan A. Lacinski and colleagues, CC BY 4.0.

[Ryan A. Lacinski e colaboradores / Bone Research](https://pmc.ncbi.nlm.nih.gov/articles/PMC11436896/) · [CC BY 4.0. Extraído painel d integral da figura1 de2024, preservando oito micrografias, rótulos e escalas500µm. Sem diagramas a/c nem ampliação.](https://creativecommons.org/licenses/by/4.0/)

## Key points

- The study compared 24 conditions using a 27-marker panel.
- Tris–EDTA and overnight incubation at 4 °C performed best under the tested conditions.
- Preparation affects cell detection and analysis without creating biological diversity.
- Technical validation does not establish clinical benefit or a universal protocol.

Preparing a tissue slide can change which proteins an imaging system detects, and therefore the cell map researchers construct. A study published on 26 November in [Nature Methods](https://www.nature.com/articles/s41592-026-03317-1) compared 24 combinations of preparation and staining for archived tissue. Tris–EDTA-based antigen retrieval followed by overnight antibody incubation at 4 °C performed best under the tested conditions.

The peer-reviewed work by Jia Le Lee, Johanna Schaffenrath, Cankun Wang, Sizun Jiang and colleagues was published as a Registered Report. It did not evaluate a treatment or demonstrate improved diagnoses in patients. It addresses an earlier question: how much sample processing changes what can be measured reproducibly.

## A map depends on signals surviving preparation

FFPE tissues are fixed in formalin and embedded in paraffin, a method of preserving samples. To image proteins, researchers cut thin sections and apply antibodies recognising specific targets. Staining allows several cell types to be located while preserving their arrangement within the tissue.

Fixation can also make antibody targets harder to reach. Antigen retrieval seeks to expose them again through chemical and heating conditions. Buffer choice, timing and incubation conditions may favour some markers while harming others.

The accompanying image is an actual example of multiplexed microscopy using PhenoCycler-Fusion, published by [Ryan Lacinski and colleagues in 2024](https://pmc.ncbi.nlm.nih.gov/articles/PMC11436896/). It shows different stains in tissue containing osteosarcoma lung metastases. It documents protein imaging that retains tissue organisation, rather than the 2026 benchmark or evidence of which preparation wins its comparison.

## Twenty-four conditions and several criteria

The main comparison used a 27-marker immune panel. The supplement identifies 25 phenotypic and functional markers in one analysis, alongside other panel stains. Those numbers do not represent 27 tissue types or 27 people.

The researchers assessed signal intensity, variation and marker failures. They also compared signal inside and outside the boundaries assigned to cells by software. A bright marker is not necessarily specific or useful if part of its response is incorrectly located.

Cell segmentation—the division of an image into individual cells—was checked using Mesmer and cellXpress2. Supplementary findings show that preparation affects both observation and subsequent analysis. Some markers had no detectable signal under particular conditions, so an absence in an image cannot automatically be interpreted as biological absence of the protein.

## Validation extended beyond one machine

After initial optimisation, the three highest-ranked conditions and one of the lowest were compared in additional combinations of institution, tissue and technology. The supplement presents eight site-and-platform configurations, including PhenoCycler, Orion, COMET, imaging mass cytometry and MIBI. Some belong to the same institution; they are not eight independent clinical trials.

Experiments included tonsil and intestinal tissue as well as several tumour tissues. Validation supports the preparation pattern beyond the first sample and instrument. It does not establish that one protocol is optimal for every antibody, organ, preservation history or future platform.

Adjacent sections of the same samples reduced biological differences between conditions. The reporting summary states that operators knew the preparation conditions, whereas pathologists were blinded when assessing performance. The experiment should therefore not be described as fully blinded.

## Brighter images do not prove greater biological diversity

The study related staining intensity to the spatial diversity its analysis could detect. Improved detection can reveal populations missed by weaker preparation. That does not mean that treating the slide created new cells or changed the tissue’s original diversity.

The supplement also identifies limits. Some correlations with quality metrics were not statistically clear, and certain analyses depend on segmentation and classification choices. The practical lesson is to compare protocols using complementary measurements rather than selecting the most visually appealing image.

The researchers provide [analysis code](https://github.com/SizunJiangLab/Benchmarking_tissue_preparation/) and data. The [pilot dataset deposit](https://zenodo.org/records/11410274) dates from 2024 and was updated in November 2026; the reviewed publication does not mean that every dataset is being disclosed for the first time. Lyntev read documentation and supplementary materials without rerunning the image analysis. The contribution is an experimental reference for making protein maps more comparable, rather than a new clinical test ready for deployment.

The [paper’s competing-interests statement](https://www.nature.com/articles/s41592-026-03317-1) identifies authors employed by Roche, Novartis and Cell Signaling Technology. Three authors hold shares in ImmunoQs, which sells image-analysis services based on cellXpress, and two are also directors. Sizun Jiang received research support from Roche and Novartis. These disclosed relationships are relevant context for interpreting a comparison involving laboratory methods and analysis software.

## Sources

- [Large-scale quantitative assessment of tissue preparation and staining conditions for robust multiplexed imaging of FFPE tissue samples](https://www.nature.com/articles/s41592-026-03317-1), Nature Methods — Jia Le Lee, Johanna Schaffenrath, Cankun Wang e colaboradores
- [Supplementary Information: figuras1–14](https://static-content.springer.com/esm/art%3A10.1038%2Fs41592-026-03317-1/MediaObjects/41592_2026_3317_MOESM1_ESM.pdf), Autores / Nature Methods
- [Reporting Summary](https://static-content.springer.com/esm/art%3A10.1038%2Fs41592-026-03317-1/MediaObjects/41592_2026_3317_MOESM2_ESM.pdf), Autores / Nature Methods
- [Benchmarking tissue preparation — analysis workflows](https://github.com/SizunJiangLab/Benchmarking_tissue_preparation/), Sizun Jiang Lab / GitHub
- [Tissue preparation and staining conditions — pilot experiment](https://zenodo.org/records/11410274), Autores / Zenodo
- [Spatial multiplexed immunofluorescence analysis reveals coordinated cellular networks associated with overall survival in metastatic osteosarcoma](https://pmc.ncbi.nlm.nih.gov/articles/PMC11436896/), Ryan A. Lacinski e colaboradores / Bone Research

Wellinton Oliveira · Lyntev